Power:8.4kw-35kw.
Function: Heating, Cooling, and Domestic hot water.
Energy Level:A+++.
Refrigerant:R32.
Noise (dB(A)):≤53.
Send Inquiry

Product Introduction Product Parameters

Working Ambient Temps Range of -30℃~43℃

The PowerWorld heat pump Adopting Panasonic EVI Full DC Inverter compressor, SHIMGE DC water pump, DC brushless motor, and Power World’s technology, this heat pump unit can stably operate in extremely cold areas of -30℃/-22℉, and output 60℃ hot water, ensuring the house heating cooling and domestic hot water is available all year round.


Energy Level A+++ Tested by TUV

Power World emphasizes increasing energy efficiency. Our Easylife Series heat pump has gained an A+++ energy label and passed the ERP test report issued by TUV SUD, meeting the EU Energy Labeling Regulation. In long-term use, its high energy efficiency can help users reduce their energy consumption.


Five Operating Modes GuaranteeYear-round Supply

Easylife series heat pump is a multi-functional unit, through the reversing operation of the three-way valve to achieve the following 5 operating modes. In addition, in the actual installation and use, it is necessary to install a buffer water tank and a domestic hot water tank in the heat pump system, which can continuously store heat for the house and make the room temperature more comfortable and constant.

  • Heating Only

  • Cooling Only

  • Domestic Hot Water Only(DHW)

  • Heating+DHW (priority)

  • Cooling+DHW (priority)


Smart Home Solutions

4 inches LCD large colorful touch cream controller, 13 different interface language options, clear letter display, and built-in wi-fi module make the remote control happen! Users can remotely control the heat pump system through a smartphone, monitor and manage the operation date anytime, anywhere, and easily create a smart home.



IoT Customer Management Platform

Power World's IoT cloud management platform can connect to Wi-Fi or DUT to realize remote monitoring and management of data. On this platform, dealers can not only manage equipment, orders, and customer information in the console but also monitor the operation of project equipment in real-time, and collect and analyze equipment operation data. For example, the fault report of the heat pump unit will be synchronized to the console of the dealer, and the dealer can quickly provide users with solutions based on the fault report.


Remote Control

Remote Monitoring

Remote Management





Hot Tags: monobloc heating air to water heat pumps, heat pump for cooling house, EVI Inverter Heat Pump, Air Source Heat Pump for home, commercial mini split heat pump, R32 Heating Heat Pump, Central Heating Air Source Heat Pump

Specification:

Product model

PW030-DKZLRS-A

PW040-DKZLRS-A

PW050-DKZLRS-A

PW060-DKZLRS-A

PW080-DKZLRS-A

PW010-DKZLRS-A

Heating

Heating Capacity Range (kW)

1.57~8.40

4.40~13.00

5.9~18.2

7.5~23.0

10.2~28.0

12.8~35.0

Heating input Range (kW)

0.32~1.87

0.90~3.02

1.20~4.11

1.53~5.23

2.07~6.36

2.61~7.99

current Range (A)

1.42~8.30

1.39~4.68/
4.12~13.8

1.86~6.37/
5.49~18.8

2.37~8.11

3.70~11.4

4.67~14.3

COP Range

4.49~4.91

4.30~4.90

4.43~4.92

4.40~4.90

4.40~4.92

4.38~4.90

Cooling

Cooling capacity Range (kW)

0.99~6.22

2.80~8.20

3.81~11.53

4.73~14.6

6.54~19.8

8.13~24.6

Cooling input power(kW)

0.29~2.18

0.85~3.31

1.11~4.05

1.39~5.14

1.92~6.97

2.42~8.75

current Range (A)

1.28~9.67

1.32~5.13/
3.89~15.1

1.72~6.28/
5.08~18.5

2.16~7.97

3.43~12.5

4.33~15.6

EER Range

2.85~3.41

2.48~3.29

2.85~3.43

2.84~3.40

2.84~3.40

2.81~3.36

DHW

Heating capacity Range (kW)

1.28~6.81

3.52~10.50

4.80~14.72

6.1~18.5

12.3~20.4

13.6~22.6

Heating input Range (kW)

0.31~2.13

0.88~3.39

1.17~4.60

1.53~5.97

2.8~5.37

3.09~5.95

current Range (A)

1.38~9.45

1.36~5.26/
4.03~15.5

1.82~7.15/
5.35~21.1

2.37~9.26

5.0~9.6

5.52~10.6

COP Range

3.2~4.1

3.1~4.0

3.2~4.1

3.1~4.0

3.8~4.4

3.8~4.4

Refrigerant

R32

Power supply

230V/1Ph/50-60Hz

230V/1Ph/50-60Hz / 380V/3Ph/50-60Hz

230V/1Ph/50-60Hz / 380V/3Ph/50-60Hz

380V/3Ph/50-60Hz

Working area

-30~43℃

Water circulation (m³/H)

1.4

2.2

3.1

4.0

4.8

6.0

Water pressure drop (kPa)

31

25

35

45

40

50

IP Grade (Level of protection)

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Noise (dB(A))

≤53

≤55

≤57

≤58

≤62

≤66

Diameter of pipe (mm)

DN25

DN25

DN25

DN25

DN32

DN32

ERP Level (35°C)

A+++

A+++

A+++

A+++

A+++

A+++

Operating water temperature (℃) DHW

9~55℃

Operating water temperature (℃) heating

9~50℃

Operating water temperature (℃) cooling

7~35℃

Remark:
Heating working condition: Inlet water temperature 30℃, Outlet water temperature 35℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.
Cooling working condition: Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
DHW working condition: Inlet water temperature 15℃, Outlet water temperature 55℃, Dry bulb temperature 7℃, Wet bulb temperature 6℃.